Lighting Calculators

Free tools for the numbers our customers ask for most — beam coverage, fixture counts and container loading — with every formula and assumption stated.

Quick Estimates, Stated Assumptions

These calculators are for rough project scoping. Every result states the formula it used, because the difference between a lighting estimate and a lighting design is knowing where the assumptions sit. For final values — especially beam spread under a specific fixture, or dimming compliance for museums and galleries — use the photometric IES data and our published verification or ask our engineering team.

Beam Coverage & Illuminance

Given a beam angle and mounting height, estimate the spot diameter and the average lux on the floor. Assumes a uniform beam and a flat surface at the mounting distance.

Spot diameter1.28 m
Coverage area1.28
Average lux (est.)783 lx

D = 2 · d · tan(θ/2), A = π·(D/2)², E ≈ Φ/A — flat surface only; real fixtures with non-uniform optics will differ. See beam comparison in our COB vs SMD guide.

Fixture Count Estimation

How many fixtures for a target lux level? Uses the Lumen Method — N = E·A / (Φ·UF·LLF) — with a utilization factor for the room surface and a light-loss factor for depreciation.

Fixtures needed35
Achieved illuminance504 lx ( target 500 lx)
Effective lumens per fixture1,440 lm

N = E·A / (Φ·UF·LLF), rounded up. UF and LLF estimates — for a real design use IES photometrics ( see lighting design guidance).

Container Loading Estimate

How many cartons fit in a 20GP or 40HQ export container? Tries all six box orientations, then takes the lower of the volume limit and the payload weight limit.

Cartons loaded225 pcs
Best packing arrangement600mm × 400mm × 400mm → 9 × 5 × 5 (length × width × height)
Volume utilization0.7%
Payload utilization0.1%

Floor-packing only (no pallets), 1–2 cm clearance is not deducted — treat as an upper bound. Contact us for a confirmed stow plan when the carton spec is final.

Why We Publish These

Buyers routinely ask how many fixtures a room needs before they ask which fixture. These three calculations were the most-requested numbers in our own project correspondence, so we published them with their math — the same way we publish our 24V vs 48V voltage-drop bench testand the engineering guides in our knowledge base.

Need the number for a real project?

Send us the room dimensions, the target lux, and the application. The engineering team turns it into a fixture schedule with IES files — free.